Search results for "Resonance frequency"
showing 10 items of 34 documents
Comparison of implant primary stability between maxillary edentulous ridges receiving intramembranous origin block grafts
2012
Purpose: The purposes of the present study were: to compare the resonance frequency analysis (RFA) values of implant placed in either ramus or calvaria block grafts; and to determine if implant diameter influences RFA implant stability quotient (ISQ) value. Material and Methods: This was a retrospective study that included 16 consecutives healthy patients treated with autogenous onlay block grafts for horizontal bone reconstruction in maxilla. Ten ramus and ten calvaria block graft treated patients were selected and compared. Results: Totally, 59 implants were placed, 35 (59.3%) were placed on the calvaria bone grafts and the remaining 24 (40.7%) were on the ramus bone graft. Of all the imp…
Enhancing the efficacy of integrative improvisational music therapy in the treatment of depression : study protocol for a randomised controlled trial
2019
Abstract Background Depression is among the leading causes of disability worldwide. Not all people with depression respond adequately to standard treatments. An innovative therapy that has shown promising results in controlled trials is music therapy. Based on a previous trial that suggested beneficial effects of integrative improvisational music therapy (IIMT) on short and medium-term depression symptoms as well as anxiety and functioning, this trial aims to determine potential mechanisms of and improvements in its effects by examining specific variations of IIMT. Methods/design A 2 × 2 factorial randomised controlled trial will be carried out at a single centre in Finland involving 68 adu…
Music Therapy for Depression Enhanced With Listening Homework and Slow Paced Breathing: A Randomised Controlled Trial
2021
Introduction: There is evidence from earlier trials for the efficacy of music therapy in the treatment of depression among working-age people. Starting therapy sessions with relaxation and revisiting therapeutic themes outside therapy have been deemed promising for outcome enhancement. However, previous music therapy trials have not investigated this issue.Objective: To investigate the efficacy of two enhancers, resonance frequency breathing (RFB) and listening homework (LH), when combined with an established music therapy model (trial registration number ISRCTN11618310).Methods: In a 2 × 2 factorial randomised controlled trial, working-age individuals with depression were allocated into gr…
Favouring emotional processing in improvisational music therapy through resonance frequency breathing: a single-case experimental study with a health…
2017
Resonance frequency breathing (RFB) is a form of slow breathing at around six breaths/min, whose immediate effects are to substantially increase heart rate variability (HRV) and to reduce stress levels. Since RFB has already been successfully used on its own to treat various emotional disorders, we wanted to evaluate its effect on emotional processing when used as a preparatory intervention in improvisational music therapy. To do so, we performed a single-subject experimental study with a healthy participant. We hypothesised that RFB would serve both as an emotional catalyst and emotional regulator, the actual outcome depending on the client’s current issues and needs. The study consisted o…
Sensitivity and Specificity of Stability Criteria for Immediately Loaded Splinted Maxillary Implants
2014
Background To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. Purpose This retrospective study aimed to assess the suitability of three stability parameters – namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values – as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. Materials and Methods Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediatel…
The effect of resonance frequency breathing when used as a preparatory exercise in music psychotherapy : A single-case experimental study of a client…
2017
This study aimed at evaluating the possible benefits of starting Integrative Improvisational Music Therapy (IIMT) sessions with 10 min of Resonance Frequency Breathing (RFB), a type of slow breathing known to be beneficial for stress reduction and emotional regulation. A client diagnosed with anxiety disorder and social phobia attended 12 IIMT sessions. Using an alternating treatments design, RFB was systematically alternated with a control intervention (vibroacoustic therapy, VAT). Therapy processes were assessed through the Session Evaluation Questionnaire (SEQ) and the continuous measurement of heart rate variability (HRV), a biomarker of autonomic nervous system response. RFB was consis…
Primary Stability of a Hybrid Self-Tapping Implant Compared to a Cylindrical Non-Self-Tapping Implant with Respect to Drilling Protocols in an Ex Viv…
2011
Background: Modifications of implant design have been intending to improve primary stability. However, little is known about investigation of a hybrid self-tapping implant on primary stability. Purposes: The aims of this study were to evaluate the primary stability of two hybrid self-tapping implants compared to one cylindrical non-self-tapping implant, and to elucidate the relevance of drilling protocols on primary stability in an ex vivo model. Materials and Methods: Two types of hybrid self-tapping implants (Straumann® Bone Level implant [BL], Straumann® Tapered Effect implant [TE]) and one type of cylindrical non-self-tapping implant (Straumann® Standard Plus implant [SP]) were investig…
Effect of implant macro-design on primary stability: A prospective clinical study
2016
Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…
Secondary implant stability outcome of immediate versus late placed variable-thread implants in the maxilla. A retrospective cohort study
2017
BACKGROUND The healing of xenograft augmentated intra-alveolar gaps following immediate implant placement (IMIP) after tooth extraction is likely to differ in time and density compared to the native bone part that directly contacts the implant. MATERIAL AND METHODS Secondary implant stability (SIS) data recorded 2-3 months following a late implant placement protocol (LIP) (n= 43) and 6-8 months following an immediate implant placement protocol (IMIP) (n=33) of variable-thread implants (Nobel Active™) in the maxilla were retrospectively collected from files of 63 patients (42 females, 21 males). Statistical analysis was performed using a generalized estimating equation model (GEE). Data spli…
A Novel Technique for Deembeding the Unloaded Resonance Frequency from Measurements of Microwave Cavities
2006
[EN] A novel technique to extract the influence of coupling networks on the resonant frequency of cavities in one-port measurements is presented. The determination of the unloaded resonant frequency is performed directly from measurements without either the need to obtain the electromagnetic fields in the resonator or to deembed the delay of transmission lines from the measuring equipment to the resonator. The importance of the Foster's form on the modeling of the frequency detuning of the resonators is also discussed and a criterion for the choice of the appropriate Foster's form is suggested. The procedure is validated with simulations and experimental measurements of manufactured cavities